TRACE HF-CCS PE45

Body designates TRACE HF-CCS PE45: annealed solid 12 AWG copper-clad steel with AISI 1006 core, 21% IACS conductivity and 45 mil HMW-HDPE. It limits tracer applications to 30 V. The shared CU category is inconsistent with the explicit CCS specification.

Historical record · current specification and availability require confirmation.

SOURCE DETAILS

What the catalog identifies

The following labels come from the historical General Clad record. Read them with the qualification notes below.

TRACE HF-CCS PE45 — historical catalog observations
Catalog referenceTRACE HF-CCS PE45
Historical catalog: applications voltage≤ 30 V — source application limit
Historical catalog: conductor size12 AWG
Historical catalog: conductivity21 %IACS
Historical catalog: steel coreAISI 1006 low carbon steel
Historical catalog: insulation thickness45 mil

Source notes for this reference

  • The page is also categorized under CU HDPE MIL TRACER WIRE; body specifies CCS, so this category is not substrate evidence.
  • Body presents 282 lb break load and 55,000 psi with 'or'; they have different dimensions and should not be treated as interchangeable quantities.
  • Embedded table is a broader CCS/PVC-or-PE range, not an exact 12 AWG PE45 SKU specification.
  • Embedded general CCS table's Density header literally reads g/m³ with values 8.0–8.4; source-unit ambiguity is unresolved.
  • Catalog voltage descriptions are source observations; suitability for the project requires review of the exact model and installation.
  • This record identifies a historical catalog entry. Current availability, approved dimensions, performance and certification are not established by the old page.

Official source body reviewed 3 October 2026. A source observation is not an approved current specification.

DEFINE THE FINISHED PRODUCT

Bring these inputs to the review

01

Identity & geometry

Confirm the exact CCS or copper substrate, conductor size, jacket material and insulation thickness.

02

Performance & process

Provide installation method, locating-system requirements, terminations and project acceptance criteria.

03

Application & supply

Request current electrical/mechanical test data for this model; broad family tables cannot establish its complete specification.

MATCH DOCUMENTS TO THE MODEL

Request the current record

Send the catalog reference with your drawing, dimensions, required performance, quantity and destination. Request a current datasheet and applicable test record for the exact finished construction. Add attachments in your email app.

The contact form prepares an email or copyable draft. It does not send the inquiry or confirm receipt.